AUTO HEMATOLOGY ANALYZER • 3-PART DIFF

VX-h360

AUTO HEMATOLOGY ANALYZER

60/hr

THROUGHPUT

9μL

MIN. VOLUME

500K

RESULTS STORED

21

PARAMETERS

Auto Hematology Analyzer (VX-h360)
Download Catalog
THROUGHPUT

60/hr

Up to 60 samples per hour in whole blood mode.
Double-channel counting for maximum efficiency.

APPLICATION

Where VX-h360
makes a difference.

Clinical Department

Emergency Laboratory

Medical Center

Research Laboratory

Examination Center

KEY FEATURES

Engineered for
high-throughput diagnostics

Double-channel counting, leading-edge detection technology, and a minimal 9µL
sample volume — all in one compact analyzer.

60 samples/hour

Throughput up to 60 samples per hour in whole blood mode with double-channel counting.

Whole Blood Mode Pre-diluted Mode

21 PARAMETERS

WBC, Lym#, Mid#, Gran#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, MPV, PDW, PCT and more — plus 3 histograms.

3 Histograms Abnormal Alarm

Minimal Sample Volume

Only 9µL of whole blood required — ideal for pediatric patients and challenging draws.

9µL Whole Blood

Leading Technology

Cell pulse baseline tracking, high voltage burning, built-in liquid sensor, and intelligent floating threshold technology.

Cyanide-Free Impedance Method

500,000 Results

Large storage capacity including histograms and full patient information. 4 USB ports and bi-directional LIS.

LIS Bi-directional 4 USB Ports

Flexible Reporting

Built-in thermal printer. Supports 5+ external HP printers. Multiple built-in report templates available.

Thermal Printer Multi-language
DETECTION

Dual-channel
precision
for complete blood
counts.

Impedance method for WBC, RBC, PLT — combined with cyanide-free colorimetric method for HGB. Intelligent floating threshold eliminates manual adjustments.

3-Part
Diff

21 PARAMETERS

WBC · RBC · HGB · HCT · PLT · Lym% · Mid% · Gran% · MCV · MCH · MCHC · RDW-CV · RDW-SD · MPV · PDW · PCT · HGB · P-LCC · P-LCR + 3 Histograms

TECHNICAL SPECS

Every detail matters.

THROUGHPUT
60 samples/hour

Whole blood mode

DETECTION CHANNEL
Double-channel for counting
SAMPLE VOLUME
Minimum 9 µL
COUNTING MODES
Whole blood mode

Pre-diluted mode

DETECTION PRINCIPLE
Impedance (WBC, RBC, PLT)

Cyanide-free colorimetric (HGB)

DETECTION ITEMS
21 PARAMETERS

+ 3 histograms, abnormal alarm

LEADING TECHNOLOGY
Cell pulse baseline tracking

High voltage burning · Liquid sensor · Intelligent threshold

REAGENT
3-Part diluent and lyse
DISPLAY
10.4" Color Touch Panel
STORAGE
500,000 results

Including histograms and patient info

INPUT / OUTPUT
4 USB ports

Bi-directional LIS · USB keyboard, mouse, disk, printer

REPORT PRINT
Built-in thermal printer

Supports 5+ external HP printers (optional)

POWER SUPPLY
100–240 VAC, 50/60 Hz

150 VA

OPERATING TEMP
10°C – 35°C

Humidity: 20%–85%

DIMENSION
420 × 295 × 430 mm
WEIGHT
≤ 28 kg
CERTIFICATIONS
TÜV · CE
LANGUAGES
Multi-language support

Customizable factory setting